PSANA 6200
Trace nitrogen analyzer
Trace Nitrogen in Argon, Helium and Crude Argon analyzer

PSANA 6200 is the new standard for trace Nitrogen.Its unique design brings reliability and accuracy needed for such measurement. Its own Plasma Emission Detector System extends the lifetime of the cell. This Duty Cycle Controlled System has the property to decrease contamination and coating inside the plasma cell giving a more efficient, reliable and accurate analyzer. Modular instrument, parts can be changed on site easily including the detector.

 

FEATURES: APPLICATIONS:
• Unique Plasma Emission Detector design based on a Duty Cycle Controlled System. • Air separation unit
Quality control for truck fills and gas cylinders
• Bootloader integrated for software update via Ethernet • Cryogenic truck loading station
• Large scale measurement • Speciality gas laboratories
• 4-20 mA output as standard • Process control
• Range Identification Relay • Argon purification plant
• Maintenance free • Steel Industries
• LAN/Web control • Chemical plants
• Micro-valve for very low dead volume and fast purging time • Welding gas control
• Low sample consumption • Helium liquification plants
• 3U cabinet • Gas management system
• Optional zero gas calibration free system • Semiconductor manufacturing

SPECIFICATIONS:

 DETECTOR TYPE   Plasma Emission Detector design based on a Duty Cycle Controlled System
 RANGE   0 – 1 ppm, resolution to 10 ppb
0 – 10 ppm, resolution to .1 ppm
0 – 100 ppm, resolution to 1 ppm
other range possible up to 10000 ppm
 ACCURACY   < 1% full scale
 RESPONSE TIME   15S for 90% of a step change at 75sccm
 REPEATABILITY   Better than ± 1% full scale
 STANDARD FEATURES   • Manual or autoranging (user selectable)
• Microprocessor controlled
• 5.6” TFT intelligent LCD module with Touch Screen
• Self diagnosis system with auto-resolve alarm
• LAN/Web control
• 4-20 mA isolated output
• Alarm Historic
• Safe calibration procedure to avoid any bad calibration
• Digital ouputs for remote monitoring: (all dry relay contacts)
- System status (1 output)
- Range in use (3 output)
- Calibration in use (1 output)
 OPTIONS   • Internal sampling system for zero, span and sample with remote capabilities
• Serial port: RS-232 / 422 / 485 / Profibus
• 2 alarm outputs (user programmable set point)
• Zero calibration gas free system
 GAS CONNECTIONS   Sample: 1/8’’ compression fittings
Vent: 1/8’’ compression fitting
 CALIBRATION GAS   Zero: purified gas (Getter), or 0.5-2.0 ppm N2/Ar
Span: 8.0 to 9.5 ppm N2/Ar
 SAMPLE FLOW REQUIREMENTS   15 to 200 sccm-
 FLOW ACCURACY   0 to 200 sccm ± 1% full scale
 MAX OPERATING PRESSURE   30 PSIG (207 kPAG)
 MIN OPERATING PRESSURE   4 PSIG (28 kPAG) optional 1 PSIG (7 kPAG)
 OPERATING TEMPERATURE   10 °C to 45 °C
 SUPPLY   115 VAC, 50 – 60 Hz or 220 VAC, 50 – 60 Hz
 POWER CONSUMPTION   Maximum 40 watts
 DRIFT   < ± 1% over 24 hours
 WEIGHT   29 lbs (13 kg)
 
Specifications are subject to change without notice.